Chorioallantoic membrane assays (HET-CAM and CAM-TBS): alternative tests for performing toxicological evaluation of products with low potential for ocular irritation

  • Amanda Gleyce Lima de Oliveira Fundação Oswaldo Cruz, Programa Institucional de Bolsas de Iniciação Científica, Rio de Janeiro, RJ
  • Ronald Santos Silva Fundação Oswaldo Cruz, Departamento de Farmacologia e Toxicologia, Rio de Janeiro, RJ
  • Eloisa Nunes Alves Fundação Oswaldo Cruz, Instituto Nacional de Controle de Qualidade em Saúde, Rio de Janeiro, RJ
  • Rosaura de Farias Presgrave Fundação Oswaldo Cruz, Departamento de Farmacologia e Toxicologia, Rio de Janeiro, RJ
  • Octavio Augusto França Presgrave Fundação Oswaldo Cruz, Departamento de Farmacologia e Toxicologia, Rio de Janeiro, RJ
  • Isabella Fernandes Delgado Fundação Oswaldo Cruz, Instituto Nacional de Controle de Qualidade em Saúde, Rio de Janeiro, RJ
Keywords: Draize test, ocular irritation, collyrium, alternative methods, sanitary surveillance, in vitro toxicology

Abstract

This study aimed at evaluating the predictive potential of the conventional Hen’s Egg Chorionallantoic Membrane (HET-CAM) test and its version CAM-TBS, that quantifies the damage to the membrane cause by absorption of dye trypan blue, in order to propose an alternative assay for assessing the ocular toxicity. Twenty collyria were evaluated in vivo by means of Draize eye irritation test, and by in vitro HET-CAM and CAM-TBS assays. All the analyzed collyria were classified as non-irritant by in vivo testing. In HET-CAM assay, 4 false positive results were observed, and the test specificity and accuracy were of 80%. CAM-TBS showed a better performance, having specificity and accuracy of 100%. The cut-off set up for HET-CAM test (0.9) is discussed, as the false-positive results observed in this study could have been bypassed if the category “non-irritant” encompassed “non-irritant” and “mild irritant” products, in compliance with the criteria recommended for CAM-TBS (cut-off = 7.0).
Published
2012-01-01
How to Cite
Oliveira, A. G. L. de, Silva, R. S., Alves, E. N., Presgrave, R. de F., Presgrave, O. A. F., & Delgado, I. F. (2012). Chorioallantoic membrane assays (HET-CAM and CAM-TBS): alternative tests for performing toxicological evaluation of products with low potential for ocular irritation. Revista Do Instituto Adolfo Lutz, 71(1), 153-159. Retrieved from https://periodicoshomolog.saude.sp.gov.br/index.php/RIAL/article/view/32405
Section
ORIGINAL ARTICLE